“NO START CONDITION”
A quick check reveals spark, fuel pressure, but no injector pulse. Car will run on an external fuel source. First item to check is the security lamp on the dash. With the ignition key on, the security lamp should illuminate for approximately 5-7 seconds, and then go off and stay off while the engine cranks. If you notice that the security lamp is flashing with the key on, or coming on while cranking, we need to examine the vehicle’s security system.
We have experienced situations where some of the vehicle’s keys may no longer start the car. The only solution to this problem is to perform a relearn of the system. In order to accomplish this, a scan tool with the necessary software is needed.